UM4 Series · DEF Tank Fill Stations

Safe DEF fills.
At grade or on the roof.

Brushed-stainless fill stations that receive DEF from delivery trucks with 85-90-95% overfill protection — the UM4S for at-grade tanks, the UM4P with an onboard pump for elevated and rooftop tanks.

UM4p product render
DEF / UREA · SAFE TANK FILLING

Choose your flow class

Sized to the tank in front of you.

Select a model to see where it fits in the family. Every class shares the same filtration, controls, and enclosure — only the flow rate changes.

UM4S

Standard Fill
Truck-supplied

The standard for filling DEF urea storage tanks. The brushed stainless-steel enclosure looks great on building walls for the long term, and accepts hose connections from pump-equipped DEF delivery trucks. Designed for 1–4 tanks with 85-90-95% high-level monitoring and overfill prevention.

Motor None
Power 120-230 VAC, 1 Phase, 50-60 HZ
Controller C1 alarms
Transfer Truck pump
Best for At-grade tanks, delivery-truck fills
Get the UM4S data sheet →

UM4P

Fill Station with Pump
10 GPM (40 LPM)

A fill station with an onboard positive-displacement pump for filling DEF urea tanks at grade, at upper levels, or on building rooftops. The same brushed-stainless weatherproof enclosure and 85-90-95% overfill protection as the UM4S, with a 10 GPM pump driven by a 1–5 HP motor.

Motor 1 - 5 HP (0.75 - 3.5 KW)
Power 120-230 VAC, 1 Phase, 50-60 HZ, Optional 3-Phase
Controller C1 alarms
Transfer Onboard pump
Best for Elevated / rooftop tanks
Get the UM4P data sheet →
Flow range
Family span · 0–300 GPM
UM4S Truck-supplied
UM4P 10 GPM (40 LPM)
0 75 150 225 300 GPM

Shared technology

The same engineering, pumped or not.

01

Architectural brushed stainless

A weatherproof NEMA 4 (IP65) enclosure with a brushed stainless-steel finish that looks right on a building wall — now and for the long term.

02

Redundant overfill protection

3-point 85-90-95% high-level sensing with an actuated fill-pipe ball valve that automatically closes on high level.

03

1–4 tanks, multi-tenant

Designed to fill one to four DEF tanks from a single station, with optional multi-tank selection for multi-tenant sites.

04

C1 controller & alarms

A C1 controller with visual and audible alarms monitors levels, with an optional analog level transmitter and display.

Model comparison

The whole family, side by side.

Model Flow Motor Power Controller Best for
UM4S Standard Fill
Truck-supplied
None
120-230 VAC, 1 Phase, 50-60 HZ
C1 alarms
At-grade tanks, delivery-truck fills
UM4P Fill Station with Pump
10 GPM (40 LPM)
1 - 5 HP (0.75 - 3.5 KW)
120-230 VAC, 1 Phase, 50-60 HZ, Optional 3-Phase
C1 alarms
Elevated / rooftop tanks

All models filter water + particulate to 1 micron · ISO 18/16/13 · NEMA 4 (IP65) · C81 controller, BACnet / Modbus

Built for safe DEF fills

Fill DEF tanks without the risk.

01

Delivery-truck hose connections

Accepts hose connections from pump-equipped DEF delivery trucks through a 2″ adapter with ball and check valves.

02

At grade or on the rooftop

The UM4S fills at-grade tanks on the truck's pump; the UM4P adds an onboard pump to reach upper levels and rooftops.

03

Automatic overfill prevention

Tank levels — particularly 85-90-95% high levels — are monitored, and actuated valves close the fill pipe on high level.

04

Spill containment built in

A 3-gallon containment basin — with optional hand pump — catches drips from hose disconnects at the fill point.

UM4

Equipment & options

Configured for your install.

Both stations ship with a complete adapter, valve, sensor, and containment package, and adapt to the tank count, mounting, and control requirements of the site.

Standard equipment
Hose adapter and cap
Ball valve and check valve
3-gallon spill containment
3-point high-level sensor (85-90-95%)
Actuated ball valve for overfill protection
C1 controller with visual & audible alarms
Brushed stainless NEMA 4 (IP65) enclosure
Options
Multi-tank selection (1–4 tanks)
Analog level transmitter & display
Hand pump for spill containment
Lockable enclosure handle
Floor-mount stand — 24″ (600 mm)
3-phase power (UM4P)

Talk to an engineer

Filling DEF tanks on your site?

Send us your tank count, tank location, and delivery method. We'll size the right UM4S or UM4P fill station and turn around datasheets, dimensional drawings, and overfill-protection specs.