UM3 Series · DEF Temperature Conditioning

DEF that's always in spec.
Heat it, or chill it.

The UM3 heater and UM3C chiller circulate DEF through storage tanks and piping to hold it in range — freeze protection in the cold, quality protection in the heat. All-stainless, 1-micron filtered, and BMS/SCADA-ready.

UM3c product render
DEF / UREA · FREEZE + HEAT PROTECTION

Choose your flow class

Sized to the tank in front of you.

Select a model to see where it fits in the family. Every class shares the same filtration, controls, and enclosure — only the flow rate changes.

UM3

Circulation Heater
3–10 GPM (12–40 LPM)

A circulation heater that maintains DEF urea temperature in storage tanks and piping to avoid service interruption from freezing. An onboard pump circulates DEF through a heating element for safe, reliable heating of steel or plastic tanks, in all-stainless construction for long-term reliability.

Motor TEFC, 0.5 to 1.0 HP (0.33 - 0.75 KW)
Power 230-480 VAC, 3 Phase, 50-60 HZ
Controller On-off + over-temp
Best for Freeze protection in cold climates
Get the UM3 data sheet →

UM3C

Chiller / Cooler
3–10 GPM (12–40 LPM)

A chiller that maintains DEF urea temperature in storage tanks and piping to avoid quality degradation from high ambient temperatures. An onboard pump circulates DEF through a heat exchanger for safe, reliable cooling of steel or plastic tanks, in all-stainless construction for long-term reliability.

Motor TEFC, 0.5 to 1.0 HP (0.33 - 0.75 KW)
Power 230-480 VAC, 3 Phase, 50-60 HZ
Controller On-off + over-temp
Best for Quality protection in warm climates
Get the UM3C data sheet →
Flow range
Family span · 0–300 GPM
UM3 3–10 GPM (12–40 LPM)
UM3C 3–10 GPM (12–40 LPM)
0 75 150 225 300 GPM

Shared technology

The same engineering, hot or cold.

01

All-stainless circulation loop

An onboard pump circulates DEF from the tank through the heating element or heat exchanger and back — 304 stainless throughout for long-term reliability.

02

Tank & piping temperature control

Maintains DEF urea temperature in storage tanks and piping to avoid service interruption from freezing or quality loss from heat.

03

1-micron filtration & sensing

Particulate filtration to 1 micron plus flow, leak, filter-DP, and temperature sensors keep the loop clean and supervised.

04

Controls & BMS / SCADA

On-off control with over-temp safety sensors, and integration to BMS and SCADA systems over BACnet or Modbus.

Model comparison

The whole family, side by side.

Model Flow Motor Power Controller Best for
UM3 Circulation Heater
3–10 GPM (12–40 LPM)
TEFC, 0.5 to 1.0 HP (0.33 - 0.75 KW)
230-480 VAC, 3 Phase, 50-60 HZ
On-off + over-temp
Freeze protection in cold climates
UM3C Chiller / Cooler
3–10 GPM (12–40 LPM)
TEFC, 0.5 to 1.0 HP (0.33 - 0.75 KW)
230-480 VAC, 3 Phase, 50-60 HZ
On-off + over-temp
Quality protection in warm climates

All models filter water + particulate to 1 micron · ISO 18/16/13 · NEMA 4 (IP65) · C81 controller, BACnet / Modbus

Built for DEF quality

Keep DEF in range, in any climate.

01

Freeze protection (cold climates)

The UM3 heater keeps DEF above freezing in tanks and piping so SCR service is never interrupted by frozen fluid.

02

Quality protection (warm climates)

The UM3C chiller holds DEF cool to prevent quality degradation from high ambient storage temperatures.

03

Steel or plastic tanks & piping

Circulation conditioning works with either tank material, adding safe, even temperature control without internal elements.

04

Comprehensive monitoring

Over-temp safety sensors and remote BMS/SCADA integration give full visibility into DEF condition and system status.

UM3c

Equipment & options

Configured for your install.

Both units ship with a complete valve, gauge, filtration, and sensor package on integral containment, and adapt to the capacity, mounting, and control requirements of the site.

Standard equipment
Inlet & outlet ball valves
Inlet Y-strainer
Outlet check valve
Inlet compound gauge (-30 to +130)
Outlet pressure gauge (0–100 PSI)
Containment basin
Particulate filter to 1 micron
Flow, leak, filter-DP & temperature sensors
Options
Heater / chiller sizing — 1 / 3 / 5 KW
Floor-mount stand — 24″ (600 mm)
BACnet / Modbus BMS & SCADA integration
CSI-format specification package
Extended temperature-range control

Talk to an engineer

Protecting DEF in a tough climate?