UM Series · DEF / Urea Pump Sets

DEF where SCR needs it.
Simplex to 100 GPM duplex.

All-stainless DEF urea pump sets that feed SCR reservoirs at emergency generators — from a compact simplex to a 100 GPM standard-flow duplex, ready to integrate with any major genset.

UM1 product render
DEF / UREA · SCR EMISSIONS CONTROL

Choose your flow class

Sized to the tank in front of you.

Select a model to see where it fits in the family. Every class shares the same filtration, controls, and enclosure — only the flow rate changes.

UM1

Simplex
3–10 GPM (12–40 LPM)

A compact simplex pump set that transfers DEF urea to reservoirs at emergency generators for SCR emissions control. Its minimal-footprint design delivers 3 to 10 GPM from an all-stainless build, mounted on integral containment with leak detection for critical applications.

Motor TEFC, 0.5 to 1.0 HP (0.33 - 0.75 KW)
Power 120-230 VAC, 1 Phase, 50-60 HZ
Controller C11
Best for Single-genset DEF transfer, minimal footprint
Get the UM1 data sheet →

UM2

Duplex · Low Flow
3–10 GPM (12–40 LPM)

A duplex, low-flow pump set that adds redundancy to DEF transfer at emergency generators. Two Viking positive-displacement pumps with auto-switch keep DEF flowing to SCR reservoirs where downtime is not an option, in the same compact all-stainless package as the UM1.

Motor TEFC, 0.5 to 1.0 HP (0.33 - 0.75 KW)
Power 120-230 VAC, 1 Phase, 50-60 HZ
Controller C12
Best for Redundant low-flow DEF for critical gensets
Get the UM2 data sheet →

UM200

Duplex · Standard Flow
5–100 GPM (20–400 LPM)

The standard-flow duplex set scales DEF transfer up to 100 GPM for multiple generators or high-volume SCR reservoirs. Redundant Viking pumps, all-stainless construction, and integral containment deliver the same critical-facility reliability across a much wider flow range.

Motor TEFC, 0.5 to 1.0 HP (0.33 - 0.75 KW)
Power 120-230 VAC, 1 Phase, 50-60 HZ
Controller C82
Best for Multi-generator, high-volume DEF supply
Get the UM200 data sheet →
Flow range
Family span · 0–400 GPM
UM1 3–10 GPM (12–40 LPM)
UM2 3–10 GPM (12–40 LPM)
UM200 5–100 GPM (20–400 LPM)
0 100 200 300 400 GPM

Shared technology

The same engineering in every set.

01

All-stainless, DEF-ready

304 stainless steel wetted parts throughout the pump, piping, and accessories stand up to corrosive DEF urea for long-term reliable performance.

02

Viking positive-displacement pumps

A proven mechanical design with strainers, check valves, ball valves, pressure / vacuum gauges, and relief valves for accurate, metered transfer.

03

Integral containment & leak detection

Each set mounts on an integral containment basin with leak-detection monitoring and a flow sensor for safe, supervised operation.

04

Integration ready

Onboard motor starter, disconnect, HOA switches, and e-stop integrate directly with CAT, Cummins, MTU, Kohler and other generator controls.

Model comparison

The whole family, side by side.

Model Flow Motor Power Controller Best for
UM1 Simplex
3–10 GPM (12–40 LPM)
TEFC, 0.5 to 1.0 HP (0.33 - 0.75 KW)
120-230 VAC, 1 Phase, 50-60 HZ
C11
Single-genset DEF transfer, minimal footprint
UM2 Duplex · Low Flow
3–10 GPM (12–40 LPM)
TEFC, 0.5 to 1.0 HP (0.33 - 0.75 KW)
120-230 VAC, 1 Phase, 50-60 HZ
C12
Redundant low-flow DEF for critical gensets
UM200 Duplex · Standard Flow
5–100 GPM (20–400 LPM)
TEFC, 0.5 to 1.0 HP (0.33 - 0.75 KW)
120-230 VAC, 1 Phase, 50-60 HZ
C82
Multi-generator, high-volume DEF supply

All models filter water + particulate to 1 micron · ISO 18/16/13 · NEMA 4 (IP65) · C81 controller, BACnet / Modbus

Built for SCR emissions control

Reliable DEF for emergency power.

01

DEF to SCR reservoirs

Transfers DEF urea to reservoirs at emergency generators so SCR systems can control emissions on demand.

02

Critical-facility reliability

Designed for emergency power at critical facilities, with duplex redundancy available where downtime is not an option.

03

Direct genset integration

Built to integrate directly into CAT, Cummins, MTU, Kohler, and other generator control and monitoring systems.

04

Compact, minimal footprint

An innovative compact design delivers 3 to 100 GPM of DEF from a small, wall- or floor-mounted footprint.

UM200 product render

Equipment & options

Configured for your install.

Every UM set ships with a complete valve, gauge, sensor, and containment package, and adapts to the enclosure, mounting, and control requirements of the site.

Standard equipment
Inlet & outlet ball valves
Inlet Y-strainer
Outlet check valve
Inlet compound gauge (-30 to +130)
Outlet pressure gauge (0–100 PSI)
Containment basin with leak sensor
Flow sensor
Motor starter panel — disconnect, HOA & e-stop
Options
Stainless steel enclosure (vs. powder-coat RAL 7035)
Floor-mount stand — 24″ (600 mm)
Level & temperature transmitters
Lead-lag / auto-switch duplex control
Modbus / BACnet to generator controls

Talk to an engineer

Adding DEF to your SCR generators?

Send us your generator make, DEF flow requirement, and redundancy needs. We'll size the right UM pump set — simplex or duplex — and turn around datasheets, dimensional drawings, and genset integration specs.