M6 Storage Series · Bulk Fuel Tanks

Bulk fuel storage.
Tank, or turnkey.

The Earthsafe M6 Storage Series holds the diesel that keeps life-safety generators running — from the M6 double-wall storage tank up to the M600, a factory-integrated tank with pumps, polishing, and controls already onboard.

M6 product render
BULK STORAGE · UL 142 / 2085

Choose your flow class

Sized to the tank in front of you.

Select a model to see where it fits in the family. Every class shares the same filtration, controls, and enclosure — only the flow rate changes.

M6

Storage Tank
250–2500 GAL

The M6 Cubic Fuel Storage Tank stores diesel for life-safety generators in a double-wall UL 142 or UL 2085 fire-rated tank. It ships with a full accessory package and the connections to add transfer pump sets that move fuel to day tanks or sub-base tanks inside the building or on the rooftop.

Approvals UL 142 / UL 2085
Controller C1 / C8 · UL 508A
Transfer Optional pump sets
Best for Bulk storage, add transfer as needed
Get the M6 data sheet →

M600

Integrated System
1000–5000 GAL

The M600 Integrated Tank System simplifies specification, purchase, installation, and operation. The bulk storage tank arrives factory-equipped with duplex transfer pumps, a tank fill system with overfill prevention, filter-polishing equipment, and integrated monitoring and controls — all wired and tested.

Approvals UL 142 / UL 2085
Controller C1 / C8 · UL 508A + HMI
Transfer Duplex pumps onboard
Best for One-spec turnkey fuel storage
Get the M600 data sheet →
Flow range
Family span · 0–1000 GAL
M6 250–2500 GAL
M600 1000–5000 GAL
0 1250 2500 3750 5000 GAL

Shared technology

The same engineering in every tank.

01

Double-wall containment

UL 142 double-wall construction with optional UL 2085 2-hour fire rating, sized to satisfy life-safety generator fuel storage requirements.

02

Fuel transfer to the engine

Transfer pump sets move fuel from bulk storage to generator day tanks or sub-base tanks — inside the building or on the rooftop.

03

Level, leak & temperature sensing

A 4- or 5-point level sensor, leak sensor, and level and temperature transmitters ship wired to the controller with a direct-read gauge.

04

C1 / C8 controls & BMS

UL 508A PLC controls with HMI. Output relays for High, Low, and Leak, plus Modbus — and optional BACnet — to building automation and generator systems.

Model comparison

The whole family, side by side.

Model Capacity Approvals Controller Factory-integrated Best for
M6 Storage Tank
250–2500 GAL
UL 142 / UL 2085
C1 / C8 · UL 508A
Tank accessory package
Bulk storage, add transfer as needed
M600 Integrated System
1000–5000 GAL
UL 142 / UL 2085
C1 / C8 · UL 508A + HMI
Pumps + polisher + controls
One-spec turnkey fuel storage

All models filter water + particulate to 1 micron · ISO 18/16/13 · NEMA 4 (IP65) · C81 controller, BACnet / Modbus

Built for in-building fuel

Safe storage and reliable transfer, right where the generator lives.

01

Safe fuel storage inside buildings

Integral secondary containment stores life-safety generator fuel safely within the building or on the rooftop.

02

Reliable refill systems

Pre-assembled, tested inlet valves, transfer pumps, and sensors are monitored and controlled by the C1 or C8 panel.

03

Integrated with building systems

Advanced controllers relay tank status to BAS, generator controls, switchgear, security, and fire-alarm systems.

04

Readily adapted for special operation

Dual inlet valves, monitored positions, overflow pumping, emergency evacuation, auto-commissioning, and fluid metering.

M600 product render

Equipment & options

Configured for your install.

Every M6 Series tank ships with a complete accessory, gauge, and sensor package. The M6 adds transfer, fill, and polishing as options — the M600 arrives with all of them factory-installed, wired, and tested.

Standard equipment
Inlet solenoid valve, strainer & ball valve
4- or 5-point level sensor + leak sensor
Level & temperature transmitters
Standard & emergency vents
Direct-read level gauge
Inspection port, cap, supply & return connections
Options · M600 standard
Duplex fuel transfer pumps
Tank fill system with overfill prevention
Fuel filter polisher
Remote fill station
UL 2085 2-hour fire rating
Modbus / BACnet connectivity

Talk to an engineer

Storing fuel for a life-safety generator?

Send us your required storage volume, run-time, code jurisdiction, and where the tank sits. We'll size the M6 or M600 and turn around datasheets, dimensional drawings, and BMS integration specs.