LM4 · Lube + Waste Oil Transfer Stations

Fresh oil in, waste out.
One station on the wall.

The LM4 stations fill lube oil tanks and remove waste oil for CHP generator sites — a truck-pumped station or one with its own onboard pump, both in an architectural brushed-stainless enclosure with 85-90-95% overfill protection.

LM4 product render
LUBE & WASTE OIL · CHP GENERATORS

Choose your flow class

Sized to the tank in front of you.

Select a model to see where it fits in the family. Every class shares the same filtration, controls, and enclosure — only the flow rate changes.

LM4

Truck-Pump Fill & Removal
Truck-supplied

The standard for filling lube oil tanks or removing waste oil for CHP applications, using the delivery truck's own pump. The architectural brushed-stainless enclosure mounts on or into a building wall, monitors 85-90-95% high levels with overfill prevention, and serves one to four lube and waste tanks.

Motor None
Power 120-230 VAC, 1 Phase, 50-60 HZ
Controller C1 controller with visual & audible alarms
Transfer Truck pump
Best for Filling & waste removal via the truck pump
Get the LM4 data sheet →

LM4P

Onboard-Pump Transfer
25 GPM (100 LPM)

The same architectural fill station with an onboard positive-displacement pump that transfers lube oil to tanks or removes waste oil from them at 25 GPM. It runs on a 1–5 HP TEFC motor, serves one to four tanks, and keeps the identical 85-90-95% overfill protection and C1 controls as the LM4.

Motor 1 - 5 HP TEFC (0.75 - 3.5 KW)
Power 120-230 VAC, 1 Phase, 50-60 HZ
Controller C1 controller with visual & audible alarms
Transfer Onboard pump
Best for Self-powered fill & waste removal
Get the LM4P data sheet →
Flow range
Family span · 0–300 GPM
LM4 Truck-supplied
LM4P 25 GPM (100 LPM)
0 25 50 75 100 GPM

Shared technology

The same engineering in both stations.

01

Fill and remove

One station fills fresh lube oil tanks and removes waste oil for CHP generator applications, through a single 2″ connection.

02

Architectural stainless

A weatherproof NEMA 4 (IP 65) brushed-stainless enclosure that looks great mounted on building walls — now and for the long term.

03

Redundant overfill protection

3-point 85-90-95% high-level sensing with an actuated ball valve that automatically closes the fill pipe on high level.

04

1–4 tanks, multi-tenant

Designed for one to four lube and waste tanks, adaptable to multi-tenant use, accepting hose connections from delivery trucks.

Model comparison

The whole family, side by side.

Model Flow Motor Power Controller Best for
LM4 Truck-Pump Fill & Removal
Truck-supplied
None
120-230 VAC, 1 Phase, 50-60 HZ
C1 controller with visual & audible alarms
Filling & waste removal via the truck pump
LM4P Onboard-Pump Transfer
25 GPM (100 LPM)
1 - 5 HP TEFC (0.75 - 3.5 KW)
120-230 VAC, 1 Phase, 50-60 HZ
C1 controller with visual & audible alarms
Self-powered fill & waste removal

Both models: lube + waste oil for CHP generators · 2″ connection · 120–230 VAC 1Ø · brushed-stainless NEMA 4 (IP 65) · 3-point 85-90-95% overfill protection · C1 controller with visual & audible alarms

Built for lube + waste oil

From the delivery truck to the tank — and back.

01

Truck delivery

The station accepts hose connections from pump-equipped lube and waste oil delivery trucks at a 2″ connection.

02

Fill fresh lube

Fresh oil is routed to one of up to four lube tanks with 85-90-95% high-level monitoring and overfill prevention.

03

Remove waste

The same station draws waste oil out of tanks for disposal or recycling through the delivery truck.

04

Powered or truck-pumped

The LM4P adds an onboard 25 GPM positive-displacement pump; the LM4 relies on the delivery truck's pump.

LM4P product render

Equipment & options

Configured for your install.

Both LM4 stations ship with a complete hose-adapter, valve, containment, and sensing package for lube and waste oil, and adapt to the tank count, pumping method, and multi-tenant requirements of the site.

Standard equipment
Hose adapter & cap (2″)
Ball valve & check valve
3-gallon spill containment basin
3-point high-level sensor (85-90-95%)
Actuated ball valve for overfill protection
C1 controller with visual & audible alarms
Brushed-stainless NEMA 4 (IP 65) enclosure
Options
Onboard PD transfer pump, 25 GPM (LM4P)
Hand pump for the containment basin
Analog level transmitter & display
Multi-tank / multi-tenant selection
Floor-mount stand, 24 in (600 mm)
Lockable enclosure handle

Talk to an engineer

Filling and draining lube oil at your CHP site?

Send us your tank count, connection point, and whether you need an onboard pump. We'll size the right LM4 station and turn around datasheets, dimensional drawings, and control specs.