C100
C200
C250
C300
C350
C400
C450
C500
C550
C600
C700
C750
C800
C900
C910
C920
C930
C931
|
Generator Tank Level Module
Duplex Pump Module
Tank Selector Module
Filter Monitor Module
Filter Control Module
Tank Fill Monitor Module
Tank
Power Fill Module
Tank Level Leak Module
Genset Tank Level Gauge
Heating Control Module
Network Interface Module
Micro Network Integrator Module
Power Switching Module
Fuel Header Control Module
Quadplex Control Module
MicroPlex Control Module
SuperDuty Level Controller
SuperDuty Tank / Pump Controller |
Monitors
level in tanks. Provides pump
on / off signals to pump control. Provides actuation
of tank inlet solenoid valves.
Starts pumps based on tank level control input.
Provides lead / lag alternation. Monitors flow
switch to auto switch to secondary pump.
Controls fuel source and return flow where multiple
fuel supply tanks are provided. Monitors low
level sensor for auto switch to secondary pump.
Monitors fuel filters for water accumulation
and differential pressure.
Controls filter circulation pump on a time cycle.
Monitors fuel filters for water accumulation
and differential pressure.
Monitors and controls bulk tank fill operations.
Provides high level warning and alarm. Operates
tank fill pipe control valve and provides pump
shut down signal.
Controls bulk tank fill pump where a fill pump
where a power fill pump is provided.
Monitors fuel tank levels and inventory and
monitors leak detection sensors for tanks and
piping.
Electronic genset tank level and volume indicator.
Designed for shallow generator base tanks.
Monitors pipe and tanks for temperature.
Controls heating devices. Provides high and
low temperature alarms.
Connects all control modules to provide complete
system information. Provides industry standard
interface to facility BMS system. Provides programmable
output relays.
Accepts inputs from third party equipment to
integrate equipment with E-Power Control Module
network.
Accepts primary and secondary system power sources.
Auto switching of power source upon failure
of primary source.
Controls flow and provides monitoring for header
type fuel systems serving multiple generators.
Integrates control functions for 1 to 4 generator
day tanks and duplex pump set.
Provides level control and pump control for
a single generator day tank.
Monitors level in tanks and provides pump on
/ off signals to pump control. Includes dual
control processors and accepts dual power sources.
Monitors primary and secondary level sensors.
Monitors primary and secondary tank inlet solenoid
valve positions. Monitors genset tank inlet
flow sensors.
Starts pumps based on tank level control input.
Provides lead / lag alternation. Monitors flow
switch to auto switch to secondary pump. Controls
fuel source tank and return flow where multiple
fuel supply tanks are provided. Monitors low
level sensor for auto switch on tank low level.
Includes dual control processors and accepts
dual power sources. |