ABN Amro Data Center, IL |
| |
The new corporate facility requires mission critical fuel systems for its integral data center. The fuel storage is (4) 12,000 gallon fuel tanks located 2 levels below grade. The system includes a specialized fill system to transfer fuel from grade into each of the bulk storage units. Earthsafe is providing a highly redundant system to provide fuel service to (7) emergency generators on the fifth floor above grade, as well as the life safety generator. |
|
 |
Intel Data Center, CA |
| |
| Earthsafe provided a 6000 gallon aboveground fire rated tank with a containment piping system to serve (3) new generators for the facility. |
|
 |
Citibank Data Center, TX |
| |
Earthsafe provided a highly redundant mission critical fuel system for a 200,000 SF data center. The system included (4) underground fuel tanks of 20,000 gallon capacity serving (10) generators of 2 MW capacity. |
|
 |
First American Data Center, CA |
| |
Highly redundant control systems were provided and commissioned by Earthsafe for the corporate data center. Dual 8,000 gallon tanks provided fuel service to (3) generators of 2 MW capacity. |
|
 |
Capital Group , CA |
| |
| The redundant fuel system for the data center included dual bulk storage tanks and pumpings units feeding 3 feeding 3 generators of 2 MW capacity. |
|
 |
Chicago Mercatile Exchange Data Center, IL |
| |
Earthsafe provided underground fuel system providing for multiple generators in the multi-tenant facility. Advanced control systems were fully integrated with the building BMS system. |
|
 |
Savvis Data Centers, CA, IL, TX |
| |
| Earthsafe provided multi-tank, multi-generator fuel systems for co-location data centers throughout the US ranging from 4 generators and 30,000 gallons of storage to 22 generators with 160,000 gallons of storage. |
|
 |
Equinix Data Centers, CA, IL, TX, NJ |
| |
| Earthsafe provided multi-tank, multi-generator fuel systems for co-location data centers throughout the US ranging from 4 generators and 30,000 gallons of storage to 8 generators with 50,000 gallons of storage |
|
 |
MCI Data Centers US National |
| |
| Earthsafe provided fuel systems for 10 facilities nationwide, typically dual 10,000 gallon tanks feeding 6 generators of 2 MW capacity. |
|
 |
Northern Trust Data Center, IL |
| |
| Earthsafe provided a remote tank fill system for a bank of 5 generators equipped with sub-base tanks. |
|
 |
Harris Bank Data Center, IL |
| |
| Earthsafe provided in-building dual bulk storage tanks, fuel polishing, and fuel transfer systems for 3 generator units with complex site conditions. |
|
 |
Qwest Data Center, IL |
| |
| Earthsafe provided dual underground fuel tanks, fuel transfer, and fuel polishing systems for 8 generater units. The extremely tight site conditions required an innovative shoring system for the tank installation. |
|
 |
Chase Data Center, IL |
| |
| Earthsafe provided mission critical fuel system controls for 6 generators at a large data center facility. Dual underground fuel tanks and pump systems transferred fuel for the 2 MW units. |
|
 |
Dell Data Center, TX |
| |
| Earthsafe provided an innovative header type fuel system for 6 generator units to meet local requirements for minimal fuel storage within the building. 5 bulk fuel tanks and pump sets provide the fuel storage and the system automatically selects the supply tanks, while controlling the return fuel flows. |
|
 |
Citadel Investments , IL |
| |
| The urban facility required fuel storage at grade with generator units on the roof of the 20 story building. Earthsafe provided the fuel storage, transfer, and control systems. |